A cavity wall tie survey involves several steps:

  • External Assessment: The surveyor examines the building’s exterior to identify construction details, the presence of a cavity, insulation, and any visible cracks or defects.

  • Locating Wall Ties: A metal detector is used to find the positions of the wall ties.

  • Inspection: Small inspection holes are drilled near the located ties, and a borescope (a type of endoscope) is used to visually assess their condition.

  • Documentation: Photographs of the wall ties are taken for further analysis and record-keeping.

This procedure is straightforward and usually takes less than an hour.